Essential Tools for Electrical Professionals
Indispensable Equipment for Every Electrician
With the following professional tools, your project will be a success in no time.
The right selection of electrical tools is crucial for the success and safety of any electrical project. Whether for installation, maintenance, or repair - the quality and functionality of the tools can significantly determine the outcome of your work. In this guide, we present you with a handpicked selection of professional tools that are distinguished by their reliability, durability, and user-friendliness.
The following tools can be purchased directly from Amazon by clicking on the image or link. We have carefully compiled this list and only included products that we exclusively work with ourselves. In the electrical field, safety is of the utmost importance, therefore, it's crucial not to save on the wrong end. The tools presented here offer excellent value for money and meet all the requirements that professional electrical tools are supposed to fulfill.
Basic Equipment for Professionals and Beginners
The basic equipment of every electrician should include at least the following tools: wire cutters, wire strippers, screwdrivers with insulated handles, voltage testers, multimeters, and a good flashlight. Each of these tools plays a crucial role in the daily work of an electrician. They not only enable efficient and precise work but also ensure your safety and that of your colleagues.
A multimeter, for example, is indispensable for troubleshooting and maintaining electrical systems. It allows for the measurement of voltage, current, and resistance, which is essential for quickly identifying and solving problems.
The key to a successful electrical installation or repair lies not only in expertise but also in the quality of the tools used.
Additional Tips and Recommendations
Beyond the basic equipment, there are further tools and devices that can improve your efficiency and safety at work. These include, among others, cable cutters for larger cable cross-sections, a ratcheting cable cutter for clean cuts without much effort, and a cable stripper that allows for the quick and precise stripping of cables without damaging them.
Another tip for electrical professionals is to invest in a high-quality tool bag or case. A well-organized tool bag not only saves time but also protects your equipment from damage and wear.
When selecting your tools, always pay attention to quality and safety certifications. Tools with a VDE mark, for example, guarantee that they meet the highest safety standards and are specifically designed for working on electrical installations.
Pliers, side cutters, cable shears... |
 | WEIDMÜLLER Cable Cutter KT 8 Length 165 mm for Cable Diameter 8 mm - Cutting tool for crush-free cutting of copper and aluminum cables up to 8 mm Ø.
- Not suitable for steel wire, steel-reinforced cables, aluminum alloys, and hard-drawn copper conductors!
- Length (mm): 165 / Width (mm): 65 / Weight (g): 180
|
 | KNIPEX 26 22 200 Flat Nose Pliers with Cutter (Stork Beak Pliers) black atramentized with multi-component sleeves 200 mm - Elastic tips: stable even when twisted
- Twist-tolerant, elastic precision tips
- Twist-tolerant, elastic precision tips
- Flat-round, long, pointed jaws
- Vanadium electric steel, forged, multi-stage oil-hardened
|
 | KNIPEX 11 02 160 Insulation Stripper black atramentized with multi-component sleeves 160 mm - For single, multiple and fine stranded conductors with plastic or rubber insulation max. Ø 5 mm or 10 mm² conductor cross-section
- Easy adjustment to the required diameter of wire or strand by knurled screw and lock nut
- Easy adjustment to the required diameter of wire or strand by knurled screw and lock nut
- Special tool steel, forged, oil-hardened
|
 | KNIPEX 70 02 160 Side Cutter black atramentized with multi-component sleeves 160 mm - The indispensable side cutter for versatile use
- High-quality material and precise workmanship for a long service life
- High-quality material and precise workmanship for a long service life
- Precision cutting edges for soft and hard wire
- Cutting edges additionally induction-hardened, cutting edge hardness approx. 62 HRC
|
Measuring devices, Duspol, voltage testers... |
  | Fluke Voltage Tester, 1 Piece, T130/VDE - More robust and user-friendly than ever before Fully meets the requirements of EN 61243-3:2010 Test type is 2-pole.
- Voltage display is LED/LCD. Voltage measurement range is 12..690 V. Internal basic load is yes. Load switchable is yes.
|
  | Fluke Multimeter, 1 Piece, 113 - 600 V, Cat 3 safety specifications
- Voltage, resistance, current, and capacitance
- Bright white backlight
- Diode test, data hold
- Input voltage AC and DC: 10 A
|
 | Fluke non-contact Voltage Tester AC 90... 600 V Electrician's Screwdriver (0 – 50 °C) - 2 sensitivity levels Detects alternating voltages from 90 V to 600 V Integrated LED flashlight CAT IV 600 V
- LVD2 is a non-contact tester with safety specification CAT IV 600 V and is suitable for commercial and industrial applications
- LVD2 has two sensitivity levels
- The device lights up blue when it is 1 to 5 inches (2.54 cm to 12.7 cm) away from the source, and red when it is immediately at the source
|
  | H+H Tool 45200 45500 VDE Standard Tester 45200/45500 Voltage Tester/Phase Tester Set up to 250V-4 pcs. (2X 45200 / 2X 45500) GS tested 0680 Made in Germany, transparent/red, 2x 140 mm / 2x 190 mm - Made in Germany
- VDE/GS tested and certified
- Hardened and galvanized screwdriver blade made of tool steel C60
- High-quality and robust design
- Simple and proven test aid as a reliable and quick phase test on electrical connections
|
Cables / Wires - stripping, skinning, cutting... |
 | Jokari Secura Super Stripper No. 15 Novelty - for precise, fast, and damage-free stripping of fire-protected cables
- razor-sharp pre-set stripping blades
- retractable trimming blade
- blades with titanium nitride coating for increased durability
- Cable stripping: Ø 8 - 13 mm, Conductor stripping: 0.2, 0.3, 0.8, 1.5, 2.5, 4.0 mm²; 24, 22, 20, 16, 14, 12 AWG
|
  | Jokari Cable Knife (Stripping Knife w. Hook Blade - Blade Titanium Nitride Coated - Working Area Ø 8-28mm) 460075 - Universal: Jokari cable knives are suitable for stripping all common round cables and are thus ideal for applications in craft and industry
- Quality: The titanium nitride coated blade has a high cutting speed, high service life, and low wear. The
- Safety: Due to soft component inserts on the handle and grip, the cable knife has a high grip security and the
- Stripping of cables can be carried out without danger
- Easy handling: The cutting depth can easily be adjusted by a set screw at the end of the handle. Automatic
- Adjustment to round and longitudinal cut possible
|
 | WEIDMÜLLER Insulation Stripper Stripax AWG 28-7 0.08-10 mm², Length 190 mm, 9005000000 - Stripping and cutting tool
- Double insulated cables in two steps without special adjustment
- Automatic opening of clamping jaws
- Stripping length adjustable with stop
- Adjustable to various insulation thicknesses
|
 | Victorinox Pocket Knife Swiss Army 1 Alox (High-Quality Alox Scales, Large Blade) silver - Slim design – cuts rope, wood, or snacks on the go. Key features: Large blade and Alox scales
- Pocket knife with 1 function and high-quality Alox scales, made in Switzerland: Large blade
- Dimensions: Height 9 mm, Length 93 mm, Weight 44 g. Article number: 0.8000.26. Article name: Swiss Army 1
|
Fine electronics, network, telephony... |
 | KNIPEX 78 03 125 Electronic Super Knips® with multi-component sleeves 125 mm - Precision pliers for the finest cutting work, e.g. in electronics and fine mechanics
- Ground, very sharp edges without bevel Shear cut with controlled micro cutting edge offset for ultra-precise cut even of the thinnest wires and long service life
- Exactly shaped tips cut through wires lying next to each other from Ø 0.2 mm
- Joint with stainless steel rivet
|
 | KNIPEX 16 60 06 SB Stripping Tool for Coaxial and Data Cables 125 mm (in SB packaging) - Universal stripping tool for coaxial cables RG 59, RG 6, RG 7, RG 11
- For stripping outer sheath, shielding, and insulation in one step
- For stripping outer sheath, shielding, and insulation in one step
- Adjustable stripping blade for data cables
- Integrated blade for cutting data cables
|
 | odedo® LSA Punch Down Tool for Installation Cables, Wall Outlets, Network Wiring, CAT 5, 6, 7, 6A - LSA punch down tool usable for flush and surface-mounted boxes, cutting off excess cable ends, standard according to EIA/TIA 568
- B for network, DSL, and ISDN
- Easy network wiring with self-cutting contacts
- Ideally usable for flush and surface-mounted boxes. Cutting cable ends in one step and easy network wiring.
|
 | CSL Network Cable Tester for RJ45 RJ11 Cables - Patch Cable Tester Line Tester - LAN Network Cable Tester - Two Different Speeds - Switch On Off - black - Use: With this CSL network cable tester, you can check your network or ISDN cables for functionality. The cable tester allows easy testing of the cable layout. / optimally suitable as a test device for checking network and communication cabling
- Function I: After you have connected the cable to the main and remote unit, you need to turn on the device. You can choose between two different speeds for this.
- Function II: Set the switch to "ON" to conduct a cable test at a moderate speed. Set the switch to "S" for the cable test to be carried out at a slow speed. The "OFF" position finally turns the device off.
|